Proper storage after separating blood serum and plasma ensures sample integrity for reliable analysis. Delays in separating blood serum and plasma or improper storage temperatures can cause rapid degradation of analytes such as glucose and cholesterol. Researchers recommend transferring serum and plasma into clean tubes, aliquoting to avoid repeated freeze-thaw cycles, and storing at -20°C or -80°C. Using a blood plasma separator can speed up separation and help maintain sample quality. Samples must be handled carefully, as temperature and moisture significantly affect stability. Following these guidelines preserves the integrity of serum and plasma samples for accurate results.

Key Takeaways

  • Separate serum and plasma from blood within 2 hours to keep samples fresh and reliable.
  • Store samples at the right temperature: short-term at 2-8°C, medium-term at -20°C, and long-term at -80°C for best preservation.
  • Divide samples into small aliquots to avoid damage from repeated freezing and thawing.
  • Label all tubes clearly with patient details and collection information to prevent mix-ups and ensure traceability.
  • Use proper packing and follow shipping rules to keep samples safe during transport and meet legal requirements.

Blood Sample Storage Guidelines

Immediate Post-Separation Steps

Proper blood sample storage guidelines begin immediately after separating serum and plasma. Following best practices during this stage preserves blood sample viability and ensures accurate results during processing and analyzing blood samples. The following steps outline essential actions for optimal sample processing:

  1. Separate serum or plasma from whole blood within 2 hours of collection. This step prevents analyte degradation and maintains sample quality.
  2. Allow blood to clot for 20 to 30 minutes at 37°C before centrifugation. This ensures complete clot formation and avoids microclot interference.
  3. Avoid premature centrifugation, which can cause microclots and affect plasma preparation.
  4. Ensure serum or plasma does not remain in contact with blood cells for more than 30 minutes. Prolonged contact can degrade important analytes.
  5. Use centrifuge stoppers to reduce evaporation and maintain anaerobic conditions. This helps preserve volatile analytes such as ethanol and ions like CO2 and calcium.
  6. If centrifugation is delayed, keep samples at room temperature. Refrigerating whole blood before separation may cause hemolysis.
  7. After separation, store serum or plasma at 4°C if testing is delayed. For longer-term storage, freeze at -20°C.
  8. Handle all samples gently to avoid trauma and hemolysis.
  9. Use appropriate anticoagulants and consider plastic beads or gel tubes to improve serum quality.
  10. Avoid exposing samples to high temperatures or vigorous handling.

Researchers recommend transferring separated serum and plasma to storage conditions within 24 hours to prevent degradation. Using a blood plasma separator can speed up plasma preparation and improve sample processing efficiency.

Aliquoting and Tube Selection

Aliquoting serum and plasma into smaller volumes is a key part of sample processing. This practice helps avoid repeated freeze-thaw cycles, which can damage sensitive analytes and reduce blood sample viability. By splitting samples into single-use aliquots, laboratories maintain the stability of both enzymatic and non-enzymatic components during storage.

  • Aliquoting reduces the risk of evaporation and aggregation. Tubes should be well filled and mixed before analysis.
  • Maintaining samples in a state close to their original collection condition is critical for usability and stability.
  • Documentation of storage conditions and aliquot formats should follow recognized storage guidelines, such as those from ISBER.
  • Automated freezers, backup cooling systems, and tracking tools help maintain sample stability over time.

Selecting the right tube for storage is also important. The table below compares polypropylene and glass tubes for long-term storage of serum and plasma:

AspectPolypropylene/COP TubesGlass Tubes
Mechanical ToughnessHigh impact resistance, resists breakageProne to breakage and shattering
Moisture BarrierGood, especially in hybrid tubesExcellent (zero WVTR)
Temperature ResistanceMaintains toughness from –70 to 121°CFragile, thermal shock risk
Shelf LifeUp to 2 years with minimal volume variationLong, but risk of breakage
Centrifugation ResistanceNo breakage under extreme centrifugationBreakage risk present

Polypropylene tubes offer durability and safety for handling and transport, especially at cold storage temperatures. Glass tubes provide an excellent moisture barrier but are fragile. Hybrid tubes combine the advantages of both materials for improved long-term storage of serum and plasma.

Sample Storage Temperatures

Proper sample storage plays a critical role in preserving the integrity and shelf life of blood serum and plasma. Selecting the correct temperature for storage depends on the intended duration and the type of analysis planned. Laboratories must follow established guidelines to ensure reliable results and minimize analyte degradation.

Short-Term Storage (2-8°C)

Short-term storage at 2-8°C is suitable for serum and plasma samples that require analysis within days. This temperature range slows down enzymatic activity and helps maintain analyte stability. Laboratories often use refrigerated storage for routine tests or when immediate analysis is not possible.

Sample Type / Test CategoryStorage TemperatureRecommended Storage Duration
Serum or Plasma (general NAT tests)2-8°CUp to 14 days depending on test
NAT samples (living donor)2-8°CCentrifuge within 72 hours to extend storage up to 12 days
Serum clot tubes2-8°CUp to 7 days (centrifuge within 72 hours)
Donor Battery samples2-8°CStable for 3 days
Recipient/Patient Battery samples2-8°CStable for 5 days

Serum and plasma samples should be separated from blood cells as soon as possible and stored in clean tubes. For most tests, the shelf life at 2-8°C ranges from 3 to 14 days. Laboratories should avoid storing whole blood at this temperature for extended periods, as this can cause hemolysis and reduce sample quality. Using a blood plasma separator can speed up the separation process, allowing for faster transfer to refrigerated storage.

Medium-Term Storage (-20°C)

Medium-term storage at -20°C is recommended for serum and plasma samples that need to be preserved for several weeks or months. Freezing at this temperature halts most enzymatic reactions and extends the shelf life of the samples.

  • Serum should be stored frozen at -20°C before DNA or RNA studies to maintain analyte integrity.
  • Plasma can be refrigerated for up to 5 days, but for longer storage, freezing at -20°C or lower is necessary.
  • Plasma samples stored at -20°C for an average of 7.6 months before shipment show minimal analyte loss, making several months a practical upper limit for this temperature.
  • Laboratories should aliquot samples into smaller volumes before freezing. This practice reduces the risk of repeated freeze-thaw cycles, which can degrade proteins and compromise data quality.

Tip: Always label aliquots clearly and record storage dates to track the shelf life of each sample.

Medium-term frozen storage is ideal for situations where analysis may be delayed or when samples need to be shipped to another facility. Proper tube selection and careful handling during freezing help maintain the quality of both serum and plasma.

separating-serum-and-plasma

Long-Term Storage (-80°C)

Long-term storage at -80°C provides the best preservation for serum and plasma samples. This temperature is essential for biobanking, research studies, and situations where samples must be stored for years.

Studies have shown that plasma and serum stored at -80°C retain most analyte stability over extended periods. For example, research on pediatric serum specimens stored at -80°C demonstrated long-term stability of biochemical markers, although specific recovery rates may vary by analyte. Another study found that tacrolimus concentrations in whole blood remained stable for nearly one year at -70°C, suggesting similar stability at -80°C.

Note: Long-term frozen storage at -80°C is considered the gold standard for specimen storage, especially for sensitive analytes and research applications.

Aliquoting remains important at this temperature. Repeated freeze-thaw cycles can cause protein degradation, especially in larger proteins. Some assays may tolerate multiple freeze-thaw events, but most guidelines recommend minimizing these cycles to preserve sample integrity. Using a membrane blood plasma separator during initial processing can further enhance sample quality before long-term storage.

Proper sample storage at -80°C ensures maximum shelf life and maintains the reliability of serum and plasma for future testing. Laboratories should monitor freezer temperatures regularly and use backup systems to prevent accidental thawing.

Labeling and Documentation

Labeling Best Practices

Accurate identification remains essential for every plasma blood sample. Proper labeling of samples prevents mix-ups and ensures reliable results. Staff should label tubes immediately after collection, using permanent markers or barcode labels. Each label must include patient identifiers such as full name, unique ID, date of birth, and collection date and time. Laboratories often specify the specimen type, for example, serum or plasma, on the label. This step supports proper identification of samples throughout processing.

Tip: Place labels flat and aligned on tubes to help barcode scanners read them without errors.

Modern laboratories use barcode tracking systems and pre-printed labels integrated with electronic medical records. These systems reduce human error and improve identification accuracy. Staff should receive regular training on labeling samples, including real-life scenarios. Understanding the differences between tube types, such as those used for serum or plasma, also helps maintain correct labeling. When using a blood plasma separator, staff should follow the same labeling protocols to ensure traceability.

Record-Keeping and Traceability

Comprehensive documentation supports traceability from collection to analysis. Each record should include collection details, such as exact time, tube type, and any additives. Processing steps, times, and temperatures must be recorded. Storage conditions, including temperature and duration, help track sample stability. Laboratories should note the number of freeze-thaw cycles and any quality issues, such as hemolysis.

A robust traceability system uses standardized coding, such as SPREC, and quality management systems like ISO 15189. Many laboratories rely on bioinformatics platforms to manage sample data securely. These systems protect privacy by using coded identifiers instead of direct personal information. Staff should document every step, from aliquoting to storage, to support reproducibility and regulatory compliance. When handling samples processed with a blood plasma separator, the same detailed records ensure proper identification of samples and maintain integrity for future research.

Sample Shipment

Packing and Temperature Control

Proper packing and temperature control play a vital role in the shipment of blood serum and plasma. Laboratories must follow strict shipping guidelines to maintain sample integrity during transport. When preparing for shipment, staff should use a watertight primary container with a leak-proof stopper. This container goes inside a secondary leak-proof container. Absorbent material between these layers helps absorb spills and cushions the contents against shocks.

For long-distance shipment, freezing the samples and using dry ice ensures viability and prevents bacterial growth. Dry ice keeps the temperature low enough to preserve analytes. Hard plastic coolers designed for pressure changes during shipping provide extra protection. Proper venting of packages is necessary because dry ice releases carbon dioxide gas as it sublimates. Labels must indicate the presence of dry ice and provide handling instructions.

Temperature guidelines for shipping are clear. If analysis occurs within 8 hours, room temperature is acceptable. For up to 7 days, refrigerated conditions between 2°C and 8°C work well. For longer periods, freezing at -15°C to -20°C with dry ice is required. Some laboratories use a blood plasma separator before shipment to speed up processing and improve sample quality. Transporting liquid blood samples safely depends on following these steps.

Regulatory Compliance

Regulatory compliance ensures the safe and legal shipment of blood serum and plasma. International and national regulations govern the shipping of these materials. Laboratories must follow:

Compliance with local, state, federal, and international laws is mandatory. Infectious substances, including blood and plasma, must meet these standards. Packages should be marked as “Exempt Human Specimen” or “Exempt Animal Specimen” to satisfy IATA and ICAO requirements. Proper packaging, marking, and labeling are essential for every shipment.

Documentation is another key part of regulatory compliance. Staff must prepare an itemized list of contents, including volume, container type, and specimen type. This list goes between the secondary and outer packaging. For certain shipments, such as Category A, a Shipper’s Declaration of Dangerous Goods is required. Labels on the outer packaging must include UN specification markings, biohazard labels, orientation arrows, and contact information for both shipper and receiver. When transporting liquid blood samples processed with a blood plasma separator, these regulations still apply.

Tip: Always check the latest regulations before each shipment to avoid delays or legal issues.

Common Storage Mistakes

Temperature Errors

Temperature errors remain one of the most common mistakes in storing blood serum and plasma. Many laboratories fail to follow standardized preanalytical guidelines, which can lead to improper storage conditions and analyte instability. Some frequent issues include not maintaining the correct temperature range, using defrosting freezers, or failing to monitor storage units. To prevent these errors, laboratories should:

  1. Use a defined storage system with separate areas for different products.
  2. Monitor temperatures continuously with recording devices and alarms.
  3. Store serum and plasma at FDA-recommended temperatures, such as -18°C for frozen plasma and 1-6°C for thawed plasma.
  4. Plan for power outages with emergency generators or validated coolers.

Tip: Regularly check alarm systems and document any corrective actions to ensure plasma and serum remain stable.

Labeling Issues

Labeling mistakes can cause serious identification problems for serum and plasma. Common errors include missing patient information, unclear handwriting, or incorrect tube labeling. When labeling issues occur, staff must relabel affected plasma or serum units by covering the original label with a new one that contains accurate information. Laboratories should also keep detailed records of any relabeling, including the reason and the affected units. If plasma containers become damaged, they should be stored separately to prevent contamination. Approval from regulatory authorities may be required for relabeling and shipping damaged plasma.

Note: Continuous education and strict adherence to labeling protocols help reduce these errors, especially when using a blood plasma separator.

Freeze-Thaw Problems

Repeated freeze-thaw cycles can damage serum and plasma, leading to changes in analyte concentrations. Studies show that multiple freeze-thaw cycles may increase plasma renin activity and decrease certain hormones, while proteins like albumin and total protein can degrade. To minimize these problems, laboratories should:

Proper aliquoting and storage protect the integrity of serum and plasma, ensuring reliable results for future analysis. Using a blood plasma separator during initial processing can further reduce the risk of freeze-thaw damage.

separate-blood-serum-and-plasma

Conclusion

Proper storage of serum and plasma protects sample quality and supports accurate laboratory results. Laboratories should control temperature, aliquot serum and plasma, and use clear labeling. Following these steps prevents degradation and mix-ups. Reliable results depend on maintaining serum and plasma at recommended temperatures and avoiding freeze-thaw cycles. Using a blood plasma separator improves processing and helps preserve serum and plasma integrity. Consistent application of these practices ensures that serum and plasma remain stable, which leads to trustworthy diagnostic outcomes.

FAQ

How Long Can Serum and Plasma Stay at Room Temperature?

Serum and plasma should not stay at room temperature for more than 2 hours. Delays can cause analyte breakdown. Using a membrane blood plasma separator helps speed up processing and reduces the risk of sample degradation.

What Is the Best Way to Avoid Freeze-Thaw Damage?

Aliquoting samples into small tubes prevents repeated freeze-thaw cycles. Laboratories should freeze each aliquot only once. This practice protects proteins and enzymes in both serum and plasma.

Which Tubes Work Best for Long-Term Storage?

Polypropylene tubes offer strong protection against breakage and temperature changes. Glass tubes provide an excellent moisture barrier but break easily. Many laboratories choose hybrid tubes for storing serum and plasma, especially when using a blood plasma separator.

Why Is Proper Labeling Important for Blood Samples?

Proper labeling prevents mix-ups and ensures traceability. Each tube should display patient information, collection date, and sample type. Barcode systems improve accuracy and reduce errors during storage and analysis.

If you are interested in our blood plasma separator, please fill out below form or send email to info@bloodplasmaseparator.com

    * Name:

    * Email:

    * Phone:

    * WhatsApp:

    * Subject:

    * Message:

      * Name:

      * Email:

      * Phone:

      * WhatsApp:

      * Subject:

      * Message:

      We use cookies in order to give you the best possible experience on our website. By continuing to use this site, you agree to our use of cookies.
      Accept