Opens in a new tab
BPS - focus on blood plasma separator manufacturing
blood-plasma-separator-9

Essential Techniques for Separating Blood and Plasma in Veterinary Practice

separating-blood-and-plasma

Veterinary professionals rely on separating blood and plasma to achieve reliable diagnostics and enhance patient care. Studies show that accurate blood and plasma separation supports safe plasma transfusions, which help manage coagulopathies and improve outcomes. In regenerative treatments for canine orthopedic injuries, the quality of platelet-rich plasma depends on precise separating blood and plasma techniques, with factors like centrifugation and patient physiology affecting the therapeutic potential. Reliable diagnostics for conditions such as bacterial sepsis in dogs also depend on accurate measurement of biomarkers, which requires high-quality plasma. Newer methods, including blood plasma separator, offer veterinarians innovative options for achieving these goals.

Key Takeaways

  • Accurate blood and plasma separation is essential for reliable veterinary diagnostics and effective patient care.
  • Choosing the right collection tube and using gentle, immediate mixing with anticoagulants preserves sample quality and prevents errors.
  • Centrifugation remains the standard method for plasma separation, producing high-quality samples but requires proper equipment and training.
  • Blood plasma separator offers a simple, fast alternative for clinics without centrifuges, though plasma quality may differ slightly.
  • Proper storage and transport of plasma samples, including refrigeration and avoiding freeze-thaw cycles, maintain sample integrity for accurate testing.

Why Separation Matters?

Diagnostic Accuracy

Veterinary professionals depend on accurate blood plasma separation to ensure reliable diagnostic tests. Many common diagnostic tests require serum or plasma from blood samples. The table below shows the wide range of tests that rely on proper separation:

Diagnostic Test CategorySpecies CoveredTest TypeSpecimen Required
Chemistry Profiles (Large Animal)Bovine, Camelid, Caprine, Equine, Ovine, PorcineClinical PathologySerum, Plasma
Chemistry Profiles (Small Animal)Canine, FelineClinical PathologySerum, Plasma
Mineral and Electrolyte PanelsVarious large and small animalsClinical PathologySerum, Plasma
Serology Tests (e.g., ELISA)Bovine, Caprine, Porcine, Equine, etc.SerologySerum, Plasma
Specific Infectious Disease TestsBovine, Porcine, Equine, AvianELISA, cELISA, PCRSerum, Plasma
Vitamin AnalysisAll speciesHPLCSerum

Plasma blood sample that is not separated promptly can lead to inaccurate clinical pathologic results. Improper or delayed separation allows ongoing cellular metabolism and hemolysis. This process alters analyte concentrations, which can cause false readings in diagnostic tests. For example, glucose levels may appear lower than they are, while potassium and phosphate may seem higher. Hemolysis also interferes with spectrophotometric assays, making diagnostics less reliable. The use of a blood plasma separator can help reduce these errors by providing rapid and efficient separation.

Sample Integrity

Sample integrity plays a critical role in the reliability of veterinary diagnostics. The preanalytical phase, which includes collection, handling, and preparation of blood, is the most error-prone stage. Errors during this phase can lead to false positives or negatives in diagnostic tests. Studies show that up to 75% of laboratory errors originate before analysis begins.

Veterinary teams must maintain strict protocols when handling blood serum or plasma. This approach ensures that diagnostics provide accurate and actionable information for patient care.

Sample Collection

Tube Selection

Veterinary professionals must select the correct tube for each blood sample collection. The choice of anticoagulant tube directly affects plasma quality and diagnostic accuracy. For plasma, lithium heparin tubes (green top) are often preferred, especially in large animals, because they allow rapid processing and higher plasma yield. EDTA tubes (purple top) work well for most mammals, particularly when measuring glucose. Citrate tubes (blue top) suit species sensitive to EDTA, such as birds and reptiles. Tubes must be filled to the indicated line to maintain the proper anticoagulant-to-blood ratio. Underfilling can cause red blood cell shrinkage and inaccurate results. Serum separator tubes are designed for serum, not plasma, and should not be used for blood plasma separation. When using advanced options like the membrane blood plasma separator, proper tube selection remains essential for optimal preparation.

Venipuncture Tips

Venipuncture technique plays a vital role in sample quality. Clean venipuncture minimizes artifacts and hemolysis. The correct needle size, such as a 22-gauge for small to medium animals, balances efficient blood flow and reduces cellular damage. Smaller syringes help prevent vein collapse. The site should be prepared by clipping fur and cleaning with an antimicrobial solution. The needle should enter bevel-up, and the vein must be stabilized to reduce trauma. Gentle withdrawal of the plunger prevents excessive negative pressure, which can cause hemolysis. After collection, blood should be transferred into tubes in the correct order to avoid cross-contamination.

Mixing and Labeling

Immediate and gentle mixing of blood with anticoagulant is critical. Tubes should be inverted several times, not shaken, to prevent clotting and preserve plasma quality. Delayed mixing or rough handling can lead to hemolysis and compromise the sample. Accurate labeling ensures that each sample is correctly identified and attributed to the right animal. Samples should be placed in designated containers and stored at the recommended temperature. Proper handling and labeling reduce errors and improve the reliability of blood samples for diagnostics and preparation, whether using traditional centrifugation or a blood plasma separator.

Separating Blood and Plasma

Centrifugation

Centrifugation remains the gold standard for separating blood and plasma in veterinary practice. This method uses centrifugal force to separate the components of blood based on density. For plasma preparation, veterinary staff typically set the centrifuge to 1,500g for 10 to 15 minutes. This speed and duration allow plasma to separate efficiently from blood cells without causing significant hemolysis. When preparing serum, a higher speed may be necessary to ensure complete separation of serum from the clot.

After centrifugation, staff must carefully transfer the plasma layer using a disposable pipette into a clean tube. This step prevents contamination with red or white blood cells. Proper technique during this stage is critical for maintaining the integrity of plasma and ensuring accurate diagnostic results. In the case of separating serum and plasma, the process requires attention to tube selection and timing to avoid mixing or loss of sample quality.

For platelet rich plasma, veterinary professionals often use a double-spin technique. The first spin occurs at 1,000g for 5 minutes, which separates plasma from blood. The second spin, at 1,500g for 15 minutes, concentrates platelets within the plasma. This method achieves up to 80% platelet recovery and increases platelet concentration by six times. The resulting platelet rich plasma contains high levels of growth factors, such as PDGF-BB, especially when activated with calcium chloride. This approach supports prp preparation for regenerative therapies in both canine and equine patients. Double-spin centrifugation produces platelet rich plasma with minimal contamination by red and white blood cells, making it suitable for clinical use.

Centrifugation offers several advantages for plasma preparation and serum preparation. It produces high-quality plasma with optimal concentrations of coagulation factors, albumin, and fibrinogen. The method also supports reliable platelet isolation for platelet rich plasma therapies. However, centrifugation requires specialized equipment, trained personnel, and adherence to strict protocols. Errors during this process, such as delayed separation or improper handling, can lead to significant preanalytical errors. Studies show that preanalytical errors account for 52% to 77% of all laboratory mistakes in veterinary clinical pathology.

Error PhaseApproximate Error Frequency (%)
Preanalytical52 – 77
Analytical4 – 14
Postanalytical9 – 21

Common sources of error include delayed centrifugation, improper plasma removal, and failure to follow standard operating procedures. For example, glucose concentrations in blood samples decrease significantly if separation of serum or plasma is delayed, which can affect diagnostic accuracy.

separate-blood-and-plasma

Blood Plasma Separator

The blood plasma separator provides an alternative to traditional centrifugation, especially in clinics with limited resources or in field settings. This device uses a hollow-fiber or membrane-based system to separate plasma from whole blood rapidly and efficiently. The process does not require a centrifuge, making it accessible and easy to use.

A comparison between blood plasma separator and centrifugation highlights key differences:

ParameterHollow-Fiber (HF) SeparatorCentrifugation (C)
Separation TimeSimilar to centrifugationSimilar to HF
Labor IntensityLower; no preparation, taring, unloading neededHigher; requires preparation and handling steps
Coagulation Times (PT, aPTT)Prolonged (e.g., PT: 9.4 s vs. 7.9 s; aPTT: 14.9 s vs. 13.1 s)Shorter coagulation times
Fibrinogen ConcentrationSignificantly decreased (1.0 g/l vs. 1.5 g/l)Higher fibrinogen concentration
Coagulation Factor Activities (FV, FVIII)Decreased (e.g., FV: 105% vs. 114%)Higher activities
Albumin ConcentrationLower (21.7 g/l vs. 23.5 g/l)Higher albumin concentration
RBC Count and HematocritSlightly lower, not statistically significantSlightly higher, not statistically significant
Clinical RelevanceDifferences significant statistically but clinical impact unclearHigher quality blood products
Practical ConsiderationEasier to use, suitable for clinics with limited resourcesRequires centrifuge and more labor

Blood plasma separator offers several practical benefits. The separator reduces labor intensity because they do not require preparation, taring, or unloading steps. The separation time is similar to centrifugation, but the process is simpler and safer. These devices are especially useful for on-site plasma preparation and for clinics that lack access to centrifuges.

Membrane-based systems produce cell-free plasma, which is preferred for certain therapeutic plasma exchange procedures and for applications that require high plasma purity. The plasma obtained is suitable for sensitive downstream analyses, such as nucleic acid amplification. However, the quality of plasma produced by blood plasma separator may differ from that produced by centrifugation. For example, coagulation times are slightly prolonged, and concentrations of fibrinogen, albumin, and coagulation factors are lower. The clinical significance of these differences remains unclear, but centrifugation generally yields higher quality blood plasma and blood serum products.

AspectMembrane Plasma SeparationCentrifugation
Plasma PurityProduces cell-free plasma preferred for therapeutic plasma exchange and online plasma fractionationMay contain residual cells, less suitable for applications requiring cell-free plasma
Application SuitabilitySuitable for on-line plasma fractionation and selective removal of macromolecules; simple and safe to applyStandard laboratory method, widely used but less suitable for on-site or therapeutic plasma exchange requiring cell-free plasma
Operational ConsiderationsInfluenced by membrane properties (hydrophilicity, pore size), blood viscosity, transmembrane pressure; membrane fouling and pore blockage possibleRequires centrifuge equipment, standard protocols; may be less portable or convenient for point-of-care or veterinary field use
Technical ComplexityMembrane characteristics and operating conditions critical; membrane modules designed with specific channel dimensions and surface areaEstablished method with known parameters; less dependent on membrane properties
Safety and SimplicityDescribed as simple and safe, competitive with other plasma separation technologiesRequires centrifuge operation, which may be more complex and less suitable for some settings

Blood plasma separator can extract large volumes of plasma from whole blood within minutes. For example, a sedimentation-assisted membrane separator can extract about 275 μL of plasma from 1.8 mL of whole blood in under 7 minutes. This method is pump-free, low-cost, and ideal for on-site testing. The plasma produced supports sensitive analyses and is sufficiently pure for most veterinary diagnostic needs.

Veterinary professionals must choose the appropriate method for separating blood and plasma based on available resources, clinical requirements, and the intended use of the plasma. Both centrifugation and blood plasma separator play important roles in plasma preparation, serum preparation, and platelet rich plasma therapies. Proper training, adherence to protocols, and awareness of potential errors ensure the highest quality results in veterinary diagnostics and treatment.

Blood Plasma Handling

Storage

Proper storage of plasma ensures reliable results in diagnostic tests. Veterinary staff should analyze plasma within one hour of separation. If immediate analysis is not possible, freezing plasma at −20°C preserves analyte stability. Storing plasma samples in primary plasma separator tubes helps maintain quality. Additive-free plastic tubes, made from medical-grade PET, reduce contamination and support plasma integrity. These tubes are sterile, single-use, and compatible with most analyzers. Both storage duration and temperature affect analyte stability. Prolonged storage or inappropriate temperatures can cause degradation or altered analyte levels. Minimizing freeze-thaw cycles is important to prevent loss of platelet function and analyte breakdown.

  • Store plasma at −20°C or between 2–8°C in the dark.
  • Use additive-free plastic tubes for storage.
  • Avoid repeated freeze-thaw cycles.
  • Ensure storage containers match the needs of the diagnostic tests.

A table below summarizes plasma stability in citrate tubes at different temperatures:

Storage TemperatureDuration TestedStability Notes for Citrated Plasma Samples
Room temperature (18-25°C)Up to 5 hoursCoagulation factors generally stable except FVIII activity decreased by ~43% after 5h
Refrigeration (2-8°C)Up to 5 hoursStable for coagulation factors and natural anticoagulants
Frozen (-15 to -25°C)Up to 4 monthsFV and FVIII activities unstable; not recommended for these factors
Deep frozen (-75 to -85°C)Up to several monthsFV and FVIII activities stable; recommended for long-term storage

Transport

Transporting plasma samples requires careful planning to protect sample integrity for diagnostic tests. Veterinary teams should use absorbent materials like polyurethane foam or bubble wrap to cushion samples. Gel packs and shock-absorbent materials help maintain temperature and reduce damage risk. Rapid transfer to the laboratory preserves plasma quality and supports timely diagnostic tests. Packaging should follow a three-layer system:

  1. Primary container: sealed tube or bag holding the plasma sample.
  2. Secondary container: includes absorbent material to contain leaks.
  3. Tertiary container: sturdy shipping box with refrigerants or cold packs and cushioning.

Maintaining the cold chain during transport is essential. Accurate labeling with animal ID, specimen type, and collection time prevents mix-ups. Complete documentation, including collection methods and special instructions, should accompany each sample. Compliance with international and national regulations, such as IATA and DOT, ensures safe and legal transport. The use of a blood plasma separator can simplify on-site plasma preparation before transport.

Troubleshooting

Common pitfalls in blood plasma handling can affect the accuracy of diagnostic tests. The table below outlines frequent issues and prevention strategies:

Common PitfallDescriptionPrevention Strategy
Nonfasted PatientLipemia increases plasma turbidity, interfering with assays.Fast patients for 8 to 12 hours before blood collection.
In vitro HemolysisHemolysis from traumatic collection, improper handling, or delays.Use atraumatic venipuncture, proper restraint, large-bore needles, gentle mixing, prompt processing. Refrigerate samples but avoid direct icing.
Clotted SamplesClotting from prolonged collection or inadequate mixing with anticoagulant.Mix with anticoagulants immediately after collection; avoid prolonged collection times; inspect for clots before analysis.
Insufficient Sample VolumeToo little blood or wrong tube size causes dilution or insufficient sample for assays.Fill tubes to the specified volume.
Improper Storage & Delayed ProcessingDelayed separation leads to analyte changes.Separate plasma promptly; refrigerate if analysis is delayed; avoid prolonged storage.

Delayed processing can cause transcriptome changes and reduce the reliability of mRNA-based diagnostic tests. The chart below shows how RNA integrity decreases over time after blood collection:

Veterinary professionals should process blood samples quickly, use proper anticoagulant tubes, and handle platelet samples gently to avoid hemolysis. Immediate separation and correct storage protect the quality of blood plasma for all diagnostic tests.

separating-plasma-and-blood

Conclusion

Veterinary teams achieve accurate diagnostics by following essential steps in blood and plasma separation. Key phases include precise sampling, correct tube selection, immediate mixing, and careful plasma extraction—whether by centrifugation or blood plasma separator. Recent innovations, such as plasma extraction cards and automated analyzers, improve efficiency and reliability.

Consistent best practices protect sample integrity and support optimal patient outcomes.

Checklist ItemBest Practice Recommendation
Tube SelectionMatch tube to test; fill to indicated volume
MixingGently invert tubes immediately after collection
SeparationUse centrifuge or blood plasma separator promptly
Storage & TransportRefrigerate or freeze; ship with cold packs and clear labels

FAQ

What Is the Main Difference Between Plasma and Serum?

Plasma contains clotting factors, while serum does not. Plasma comes from blood collected in tubes with anticoagulant. Serum forms after blood clots. Both support diagnostic tests, but plasma is often preferred for rapid analysis.

How Does a Blood Plasma Separator Work?

A blood plasma separator uses a special filter to separate plasma from whole blood. The device does not need a centrifuge. It provides quick, cell-free plasma, which helps in field settings or clinics with limited equipment.

Why Is Immediate Mixing of Blood with Anticoagulant Important?

Immediate mixing prevents clot formation. Clots can trap cells and change test results. Gentle inversion of the tube ensures even distribution of the anticoagulant. This step protects sample quality for accurate diagnostics.

How Should Veterinary Staff Store Plasma Samples?

Veterinary staff should store plasma at −20°C or between 2–8°C. They should use additive-free plastic tubes. Avoiding repeated freeze-thaw cycles keeps analytes stable. Proper storage ensures reliable test results.

Can Blood Plasma Separator Replace Centrifugation in all Cases?

Blood plasma separator offers a good alternative for many situations. However, centrifugation still produces higher quality plasma for some tests. Veterinary professionals should choose the method based on clinical needs and available resources.

If you are interested in our blood plasma separator, please fill out below form or send email to info@bloodplasmaseparator.com

    * Name:

    * Email:

    * Phone:

    * WhatsApp:

    * Subject:

    * Message:

      * Name:

      * Email:

      * Phone:

      * WhatsApp:

      * Subject:

      * Message:

      We use cookies in order to give you the best possible experience on our website. By continuing to use this site, you agree to our use of cookies.
      Accept