Plasma contains clotting factors and is separated from blood treated with anticoagulants, while serum forms after blood clots and lacks most clotting proteins.
Using the right blood collection tubes and anticoagulants is crucial to obtain pure plasma or serum samples and avoid contamination or clotting errors.
Prompt processing and correct centrifugation settings prevent hemolysis and maintain sample quality for accurate laboratory tests.
Blood plasma separator and microfluidic system offer gentle, efficient alternatives to centrifugation, improving plasma purity and reducing cell damage.
Proper labeling, storage, and transport of plasma and serum samples ensure traceability and preserve analyte stability for reliable research results.
Plasma and Serum Basics
Plasma
Plasma makes up about 55% of total blood volume. This pale yellow liquid suspends blood cells and serves as the main medium for transporting nutrients, hormones, and waste products. Plasma contains water, proteins, glucose, minerals, and dissolved gases. It plays several vital roles in the body. The table below summarizes its main biological functions and key components:
Biological Function
Description
Key Plasma Components Involved
Transport of cells and substances
Carries blood cells, nutrients, hormones, waste, gases, and electrolytes
Water, proteins, nutrients, hormones
Maintenance of osmotic pressure
Balances water between blood and tissues, preventing swelling
Albumin
pH balance
Keeps blood slightly alkaline by binding excess hydrogen ions
Plasma proteins
Blood clotting
Forms clots to prevent blood loss and infection
Fibrinogen, clotting factors
Immune response
Supports immune and inflammatory reactions
Complement proteins, gamma globulins
Cellular communication
Regulates cellular processes through signaling molecules
Cytokines
Waste transport
Moves nitrogenous wastes like urea to the kidneys
Nitrogenous compounds
Gas transport
Carries oxygen and carbon dioxide dissolved in plasma
Dissolved gases (O2, CO2)
Nutrient transport
Delivers glucose, fats, amino acids, minerals, and vitamins
Nutrients
Plasma retains all clotting factors, which is important for certain blood separation techniques. Researchers often use a blood plasma separator toisolate plasma from blood, ensuring that rbcs, wbcs, and platelets remain suspended until centrifugation.
Serum
Serum is the liquid portion of blood that remains after clotting. During the clotting process, fibrinogen converts to fibrin, forming a clot that traps rbcs, wbcs, and platelets. After removing the clot, the remaining fluid is serum. Serum contains antibodies, hormones, electrolytes, and other proteins, but it lacks most clotting factors. The process of obtaining serum involves allowing blood to clot, then using centrifugation to separate the liquid from the cells and clot. Many clinical tests use serum samples because the absence of clotting proteins can reduce interference in some assays. However, the clotting process can activate platelets, which release additional proteins and alter the composition of serum compared to plasma.
Key Differences
Plasma and serum differ in their preparation, composition, and clinical uses. The table below highlights these differences:
Component/Characteristic
Serum
Plasma
Definition
Liquid after blood clots
Liquid with clotting prevented by anticoagulants
Clotting factors
Absent
Present
Blood cells
Absent
Present (before centrifugation)
Antibodies, hormones, electrolytes
Yes
Yes
Collection method
Blood clots, then centrifuged
Blood with anticoagulant, then centrifuged
Use in clinical testing
Preferred when clotting factors interfere
Preferred for coagulation studies
Protein composition
Altered by clotting and platelet activation
Retains clotting proteins
Plasma samples retain clotting proteins, while serum samples lose many of these during clot formation.
Blood separation techniques, such as using a blood plasma separator, help isolate plasma without triggering clotting.
Both plasma and serum lack rbcs and wbcs after centrifugation, but the initial handling of blood and the separation process affect the final composition of the samples.
Tip: Choosing the right sample type and blood separation technique is crucial for accurate laboratory results, especially when analyzing proteins or studying cell-free components.
Preserves glucose; used in GTT, lactic acid tests; mix 8-10 times
Light Blue Sodium Citrate Coagulation
Buffered 3.2% sodium citrate (anticoagulant)
Coagulation studies; requires exact fill volume; mix 3-4 times
The choice of anticoagulant or clot activator directly affects plasma yield and purity. For example, EDTA, heparin, and citrate prevent clotting by different mechanisms, which can influence the measurement of small molecules and metabolic profiles. Rapid serum tubes with advanced clot activators like RAPClot™ allow high-quality serum isolation even from anticoagulated blood, improving both yield and purity. Leading brands such as BD Vacutainer® and Greiner Bio-One provide reliable tubes for clinical and research laboratories.
Centrifuges and Parameters
Centrifugation remains the most widely used method for blood separation techniques. Laboratories prefer swing-out (horizontal) centrifuges because they improve plasma purity and reduce cell damage. The table below outlines key centrifuge parameters:
Parameter
Recommendation / Range
Temperature
Room temperature (20°C–24°C); 12°C–16°C for improved platelet recovery
Centrifuge Type
Swing-out (horizontal) preferred
Centrifugation Steps
Double centrifugation increases platelet concentration; single step for PRP gel
Speed (rpm or g-force)
Adjust according to tube and protocol
Duration (time)
Follow tube and assay guidelines
Routine maintenance and calibration ensure optimal blood cell isolation and plasma quality. Staff should clean rotors, inspect for wear, calibrate equipment, and balance samples. Regular professional servicing and detailed record-keeping help maintain reliable operation.
Note: Proper centrifuge settings and maintenance prevent cell lysis and contamination, which can compromise plasma and serum samples.
Blood Plasma Separator
Blood plasma separator offers an efficient alternative to traditional centrifugation. These devices use vertical membranes to gently capture cells, reducing hemolysis and improving plasma purity. They require smaller blood volumes and operate without electrical power, making them ideal for point-of-care and resource-limited settings. Processing time is shorter, and the risk of contamination decreases. Microfluidic devices represent another advancement in blood separation techniques. These compact systems automate plasma and serum isolation, require minimal blood, and achieve high purity. They support rapid, stable testing and integrate easily with downstream analysis.
Blood plasma separator and microfluidic device have transformed blood cell isolation. They provide high-quality plasma for diagnostics and research, especially where traditional centrifugation is impractical.
Separation of Plasma and Serum from Blood
Plasma Separation Steps
The separation of plasma from blood is a critical process in laboratory research. This procedure ensures that plasma samples remain uncontaminated and suitable for downstream analysis. Laboratories follow a precise sequence to achieve effective plasma separation and maintain sample integrity.
Collect whole blood in tubes designed for plasma isolation. These tubes often contain anticoagulants such as EDTA, heparin, or citrate. Tube sizes can range from 1.5 mL to 15 mL.
Gently invert the tubes 5–10 times to mix the blood with the anticoagulant. This step prevents clotting and supports proper blood cell isolation.
Process the blood sample as soon as possible. Delays longer than 24 hours can compromise the quality of the plasma sample. For best results, centrifuge within 3 hours of collection.
Select the appropriate centrifuge. Clinical laboratories often use swing-out rotors for better rbc separation and white blood cell isolation. Research settings may use fixed-angle rotors for higher speeds.
Set the centrifuge to 2500–4000 rpm (up to 2270 g) for most diagnostic assays. For rapid separation, speeds up to 6500 rpm (3873 g) may be used. Centrifuge for less than 15 minutes.
After centrifugation, observe the layers. The top layer contains straw-colored plasma, which makes up about 55% of the blood volume. The middle buffy coat holds wbcs and platelets. The bottom layer contains rbcs.
Carefully extract the plasma layer using a pipette. Avoid disturbing the buffy coat and rbcs to prevent contamination.
Transfer the plasma to a clean, labeled tube for storage or analysis.
Tip: Using a blood plasma separator or microfluidic device can improve plasma purity and reduce hemolysis, especially in settings without access to centrifugation.
Critical points during plasma separation include prompt processing, correct centrifugation speed, and gentle handling. Delayed centrifugation or rough handling can cause hemolysis, releasing intracellular contents from rbcs and wbcs into the plasma. This contamination affects the accuracy of laboratory assays and may require re-testing.
Serum Samples Preparation
Serum samples require a different approach because the blood must clot before separation. Proper timing and temperature control are essential for high-quality serum.
Step
Description
Timing Control
Temperature Control
Blood Collection
Draw whole blood into a red-top or serum separator tube.
Centrifuge with stopper up at recommended speed (2500–3000 rpm).
No more than 10 minutes
Avoid prolonged centrifugation
Serum Separation
Aspirate serum without disturbing the cell layer.
Separate within 2 hours of collection
Inspect for hemolysis and turbidity
Labeling and Transport
Label tubes with all required information.
N/A
Send at room temperature unless freezing is required
Frozen Serum Handling
Transfer to plastic tubes and freeze if needed.
Freeze immediately after separation
Store at 0°C to -20°C or -70°C as required
Transport Considerations
Use frozen gel packs for frozen samples.
Keep frozen until pickup
Maintain frozen state during transport
Serum samples must be separated from cells within two hours of venipuncture. This step prevents cellular metabolism from altering the serum composition. Allow the blood to clot for 30–60 minutes at room temperature. Do not disturb the tube during this period. After clotting, centrifuge the tube for up to 10 minutes. Carefully aspirate the serum, avoiding the rbcs and wbcs at the bottom. Inspect the serum for hemolysis or turbidity, which can indicate contamination or poor sample quality.
Note: Delayed centrifugation beyond 3–8 hours at room temperature can cause significant changes in analytes such as potassium, urea, and enzymes. Laboratories should process serum samples promptly to maintain accuracy.
Sample Handling and Labeling
Proper sample handling and labeling are essential for traceability and reliable results in the separation of plasma and serum from blood. Laboratories follow strict protocols to prevent mix-ups and maintain sample integrity.
Include essential information on each label: protocol number, subject or animal number, visit or time, matrix, anticoagulant, and a unique identifier such as an accession number.
Do not use personal identifiers like names to protect privacy.
Place labels on the tube body, not on the cap or near moisture-prone areas. This practice prevents detachment and allows visual inspection of sample volume.
Employ barcodes or QR codes for efficient tracking and integration with electronic systems.
Record all labeling activities in traceability logs, including dates, times, operator identity, and sample status.
Maintain chain of custody by documenting sample location, storage conditions, and any time spent outside storage. Track the number of freeze-thaw cycles for each sample.
Use Laboratory Information Management Systems (LIMS) when available to maintain audit trails and improve traceability.
Store plasma and serum samples under conditions that preserve analyte stability. Refrigerate or freeze samples immediately after centrifugation as required.
Prepare a shipment inventory for each batch of samples, detailing all identifiers and storage conditions. Ship samples with dry ice or refrigerated packs to maintain stability during transport.
International standards from organizations such as ICSH, CLSI, and EFLM recommend labeling tubes before collection whenever possible. Labels should never fully wrap the tube, ensuring that laboratory staff can inspect the sample visually. Following these best practices reduces the risk of misidentification, contamination, and sample loss.
Improper handling of plasma and serum samples can lead to issues such as fibrin strands, microclots, hemolysis, and cellular contamination. These problems compromise the accuracy of laboratory assays and may require re-testing, increasing workload and costs.
The separation of plasma and serum from blood relies on precise timing, careful handling, and strict adherence to labeling protocols. By following these steps, laboratories can ensure high-quality plasma and serum samples for research and clinical applications.
Best Practices and Troubleshooting
Avoiding Hemolysis
Hemolysis, the rupture of rbcs, remains a leading cause of sample rejection in laboratory research. This problem affects the accuracy of quantitative analysis and reduces the purity of plasma and serum. Most hemolysis occurs during blood collection or handling. The following table summarizes common causes and strategies to minimize hemolysis:
Implement strict laboratory guidelines for sample handling and timely processing
Major pre-analytical factors causing in vitro hemolysis
Use of vacuum tubes with high suction pressure
Use low vacuum tubes especially in sensitive populations like pediatric patients
Studies show reduction in hemolysis with low vacuum tubes
Laboratories should gently invert tubes after collection, avoid using IV catheters, and process blood quickly. Proper technique during white blood cell isolation also reduces cell damage. Using a blood plasma separator can further protect rbcs and wbcs from mechanical stress, improving sample integrity.
Preventing Contamination
Contamination can compromise the isolation and purity of plasma and serum, affecting downstream quantitative analysis. Laboratories follow these best practices:
Perform regular quality control checks to detect errors early.
Maintain accurate documentation for every step, ensuring traceability and sample integrity.
Follow regulatory guidelines from organizations such as the FDA and CLIA.
Common errors include clotted samples, improper mixing, and labeling mistakes. The chart below shows the main reasons for sample rejection:
Strict adherence to protocols and the use of technologies like barcoding help reduce contamination and improve the reliability of blood cell isolation.
Select the correct color-coded tube for blood collection.
For serum, allow blood to clot for at least 30 minutes; for plasma, mix with anticoagulant before centrifugation.
Transfer plasma or serum into leak-proof plastic tubes.
Use DOT-compliant transport tubes and pack samples in temperature-controlled racks.
Follow DOT and IATA regulations for shipping.
Plasma and serum remain stable at 4°C for up to six months and at −20°C for up to one year. For long-term storage, −80°C is recommended to prevent degradation of sensitive analytes. Laboratories should minimize freeze-thaw cycles and use gradual thawing methods to maintain sample quality. Temperature fluctuations can alter concentrations of glucose, potassium, and other analytes, so prompt separation and cooling are essential.
Tip: Using a blood plasma separator and following best practices for storage and transport ensures high sample purity and reliable results in laboratory research.
Conclusion
Laboratory professionals achieve high-quality plasma and serum samples by following essential steps and using the right materials. The table below outlines key recommendations:
Step/Aspect
Serum Separation
Plasma Separation
Clot Formation Time
30–60 minutes at room temperature
N/A
Holding Temperature
After clotting, hold at 4 °C for ≤4 h
Hold at 4 °C for ≤4 h before processing
Centrifugation Timing
Immediately after clot formation or within 4 h
Immediate processing or within 4 h
Collection Tubes
Tubes without additives, for serum
EDTA tubes preferred for plasma
Anticoagulant Choice
N/A
EDTA preferred
Temperature Control
Room temp for clotting; 4 °C for holding; −80 °C for storage
Same as serum; control during collection, transport, storage
Aliquoting
Prepare small aliquots
Same as serum
Documentation
Record all handling times, temperatures, steps
Same as serum
Light Sensitivity
Protect from light
Same as serum
Strict adherence to best practices—such as using blood plasma separator, proper tube, and correct centrifugation—reduces errors and improves sample integrity. Studies show that compliance with guidelines enhances laboratory result quality, minimizes hemolysis, and ensures reliable data for research and clinical care.
FAQ
What Is the Main Difference Between Plasma and Serum?
Plasma contains clotting factors, while serum does not. Plasma comes from blood treated with anticoagulants. Serum forms after blood clots. Researchers often use a blood plasma separator to isolate plasma for laboratory analysis.
Why Do Laboratories Use Blood Plasma Separator?
Blood plasma separator helps laboratories quickly and gently separate plasma from blood cells. These devices reduce hemolysis and contamination. They also work well in settings without access to centrifuges.
How Can Hemolysis Be Prevented During Blood Collection?
Staff should use the correct needle size and avoid excessive suction. Gentle mixing and prompt processing help prevent hemolysis. Using a blood plasma separator can further protect red blood cells from damage.
How Should Plasma and Serum Samples Be Stored?
Laboratories store plasma and serum at 4°C for short-term use. For long-term storage, they freeze samples at −20°C or −80°C. Proper storage preserves analyte stability and prevents sample degradation.
Can Plasma and Serum Be Used Interchangeably in All Tests?
No. Some tests require plasma because it contains clotting factors. Others need serum to avoid interference from those proteins. Researchers must choose the correct sample type and separation method for accurate results.
If you are interested in our blood plasma separator, please fill out below form or send email to info@bloodplasmaseparator.com
We use cookies in order to give you the best possible experience on our website. By continuing to use this site, you agree to our use of cookies.