The separation of plasma and serum from blood forms a foundation for many analytical tests in laboratory research. Laboratories worldwide rely on rapid separation to maintain the stability of key analytes, especially when handling samples for renal and cardiac markers. Researchers use centrifugation or advanced methods such as blood plasma separator to process blood and obtain high-quality samples. Delays in separation or improper handling can lead to errors, with pre-analytical issues accounting for most laboratory mistakes. Accurate separation ensures reliable research results and supports clinical decision-making.

Key Takeaways

  • Plasma contains clotting factors and is separated from blood treated with anticoagulants, while serum forms after blood clots and lacks most clotting proteins.
  • Using the right blood collection tubes and anticoagulants is crucial to obtain pure plasma or serum samples and avoid contamination or clotting errors.
  • Prompt processing and correct centrifugation settings prevent hemolysis and maintain sample quality for accurate laboratory tests.
  • Blood plasma separator and microfluidic system offer gentle, efficient alternatives to centrifugation, improving plasma purity and reducing cell damage.
  • Proper labeling, storage, and transport of plasma and serum samples ensure traceability and preserve analyte stability for reliable research results.

Plasma and Serum Basics

Plasma

Plasma makes up about 55% of total blood volume. This pale yellow liquid suspends blood cells and serves as the main medium for transporting nutrients, hormones, and waste products. Plasma contains water, proteins, glucose, minerals, and dissolved gases. It plays several vital roles in the body. The table below summarizes its main biological functions and key components:

Biological FunctionDescriptionKey Plasma Components Involved
Transport of cells and substancesCarries blood cells, nutrients, hormones, waste, gases, and electrolytesWater, proteins, nutrients, hormones
Maintenance of osmotic pressureBalances water between blood and tissues, preventing swellingAlbumin
pH balanceKeeps blood slightly alkaline by binding excess hydrogen ionsPlasma proteins
Blood clottingForms clots to prevent blood loss and infectionFibrinogen, clotting factors
Immune responseSupports immune and inflammatory reactionsComplement proteins, gamma globulins
Cellular communicationRegulates cellular processes through signaling moleculesCytokines
Waste transportMoves nitrogenous wastes like urea to the kidneysNitrogenous compounds
Gas transportCarries oxygen and carbon dioxide dissolved in plasmaDissolved gases (O2, CO2)
Nutrient transportDelivers glucose, fats, amino acids, minerals, and vitaminsNutrients

Plasma retains all clotting factors, which is important for certain blood separation techniques. Researchers often use a blood plasma separator to isolate plasma from blood, ensuring that rbcs, wbcs, and platelets remain suspended until centrifugation.

Serum

Serum is the liquid portion of blood that remains after clotting. During the clotting process, fibrinogen converts to fibrin, forming a clot that traps rbcs, wbcs, and platelets. After removing the clot, the remaining fluid is serum. Serum contains antibodies, hormones, electrolytes, and other proteins, but it lacks most clotting factors. The process of obtaining serum involves allowing blood to clot, then using centrifugation to separate the liquid from the cells and clot. Many clinical tests use serum samples because the absence of clotting proteins can reduce interference in some assays. However, the clotting process can activate platelets, which release additional proteins and alter the composition of serum compared to plasma.

Key Differences

Plasma and serum differ in their preparation, composition, and clinical uses. The table below highlights these differences:

Component/CharacteristicSerumPlasma
DefinitionLiquid after blood clotsLiquid with clotting prevented by anticoagulants
Clotting factorsAbsentPresent
Blood cellsAbsentPresent (before centrifugation)
Antibodies, hormones, electrolytesYesYes
Collection methodBlood clots, then centrifugedBlood with anticoagulant, then centrifuged
Use in clinical testingPreferred when clotting factors interferePreferred for coagulation studies
Protein compositionAltered by clotting and platelet activationRetains clotting proteins
  • Plasma samples retain clotting proteins, while serum samples lose many of these during clot formation.
  • Blood separation techniques, such as using a blood plasma separator, help isolate plasma without triggering clotting.
  • Proteomics studies show that plasma better reflects in vivo conditions, while serum can undergo more protein degradation and modification.
  • Both plasma and serum lack rbcs and wbcs after centrifugation, but the initial handling of blood and the separation process affect the final composition of the samples.

Tip: Choosing the right sample type and blood separation technique is crucial for accurate laboratory results, especially when analyzing proteins or studying cell-free components.

Materials and Equipment

Blood Collection Tubes

Selecting the correct blood collection tube is essential for successful plasma and serum separation. Each tube contains specific additives that influence blood cell isolation and sample quality. The table below summarizes the most common tubes, their additives, and their primary uses:

Tube Name / ColorAdditivesFunction / Notes
Gold Serum Separation (SST)No anticoagulant; clot activator (micronized silica); polymer gel separatorSerum separation with barrier; mix by inverting 5 times
Light Green Lithium Heparin PSTLithium Heparin; polymer gel separatorPlasma separation; inhibits clotting; mix 8-10 times
Lavender K2EDTAK2EDTA (liquid)Anticoagulant by calcium binding; ideal for CBC; mix 8-10 times
Grey Sodium Fluoride & Potassium OxalatePotassium oxalate (anticoagulant); sodium fluoride (glycolysis inhibitor)Preserves glucose; used in GTT, lactic acid tests; mix 8-10 times
Light Blue Sodium Citrate CoagulationBuffered 3.2% sodium citrate (anticoagulant)Coagulation studies; requires exact fill volume; mix 3-4 times

The choice of anticoagulant or clot activator directly affects plasma yield and purity. For example, EDTA, heparin, and citrate prevent clotting by different mechanisms, which can influence the measurement of small molecules and metabolic profiles. Rapid serum tubes with advanced clot activators like RAPClot™ allow high-quality serum isolation even from anticoagulated blood, improving both yield and purity. Leading brands such as BD Vacutainer® and Greiner Bio-One provide reliable tubes for clinical and research laboratories.

Centrifuges and Parameters

Centrifugation remains the most widely used method for blood separation techniques. Laboratories prefer swing-out (horizontal) centrifuges because they improve plasma purity and reduce cell damage. The table below outlines key centrifuge parameters:

ParameterRecommendation / Range
TemperatureRoom temperature (20°C–24°C); 12°C–16°C for improved platelet recovery
Centrifuge TypeSwing-out (horizontal) preferred
Centrifugation StepsDouble centrifugation increases platelet concentration; single step for PRP gel
Speed (rpm or g-force)Adjust according to tube and protocol
Duration (time)Follow tube and assay guidelines

Routine maintenance and calibration ensure optimal blood cell isolation and plasma quality. Staff should clean rotors, inspect for wear, calibrate equipment, and balance samples. Regular professional servicing and detailed record-keeping help maintain reliable operation.

Note: Proper centrifuge settings and maintenance prevent cell lysis and contamination, which can compromise plasma and serum samples.

Blood Plasma Separator

separation-of-plasma-and-serum

Blood plasma separator offers an efficient alternative to traditional centrifugation. These devices use vertical membranes to gently capture cells, reducing hemolysis and improving plasma purity. They require smaller blood volumes and operate without electrical power, making them ideal for point-of-care and resource-limited settings. Processing time is shorter, and the risk of contamination decreases. Microfluidic devices represent another advancement in blood separation techniques. These compact systems automate plasma and serum isolation, require minimal blood, and achieve high purity. They support rapid, stable testing and integrate easily with downstream analysis.

Blood plasma separator and microfluidic device have transformed blood cell isolation. They provide high-quality plasma for diagnostics and research, especially where traditional centrifugation is impractical.

Separation of Plasma and Serum from Blood

Plasma Separation Steps

The separation of plasma from blood is a critical process in laboratory research. This procedure ensures that plasma samples remain uncontaminated and suitable for downstream analysis. Laboratories follow a precise sequence to achieve effective plasma separation and maintain sample integrity.

  1. Collect whole blood in tubes designed for plasma isolation. These tubes often contain anticoagulants such as EDTA, heparin, or citrate. Tube sizes can range from 1.5 mL to 15 mL.
  2. Gently invert the tubes 5–10 times to mix the blood with the anticoagulant. This step prevents clotting and supports proper blood cell isolation.
  3. Process the blood sample as soon as possible. Delays longer than 24 hours can compromise the quality of the plasma sample. For best results, centrifuge within 3 hours of collection.
  4. Select the appropriate centrifuge. Clinical laboratories often use swing-out rotors for better rbc separation and white blood cell isolation. Research settings may use fixed-angle rotors for higher speeds.
  5. Set the centrifuge to 2500–4000 rpm (up to 2270 g) for most diagnostic assays. For rapid separation, speeds up to 6500 rpm (3873 g) may be used. Centrifuge for less than 15 minutes.
  6. After centrifugation, observe the layers. The top layer contains straw-colored plasma, which makes up about 55% of the blood volume. The middle buffy coat holds wbcs and platelets. The bottom layer contains rbcs.
  7. Carefully extract the plasma layer using a pipette. Avoid disturbing the buffy coat and rbcs to prevent contamination.
  8. Transfer the plasma to a clean, labeled tube for storage or analysis.

Tip: Using a blood plasma separator or microfluidic device can improve plasma purity and reduce hemolysis, especially in settings without access to centrifugation.

Critical points during plasma separation include prompt processing, correct centrifugation speed, and gentle handling. Delayed centrifugation or rough handling can cause hemolysis, releasing intracellular contents from rbcs and wbcs into the plasma. This contamination affects the accuracy of laboratory assays and may require re-testing.

Serum Samples Preparation

Serum samples require a different approach because the blood must clot before separation. Proper timing and temperature control are essential for high-quality serum.

StepDescriptionTiming ControlTemperature Control
Blood CollectionDraw whole blood into a red-top or serum separator tube.Label immediately after collectionNo special temperature at this stage
ClottingAllow blood to clot upright at room temperature.30–60 minutesDo not remove stopper during clotting
CentrifugationCentrifuge with stopper up at recommended speed (2500–3000 rpm).No more than 10 minutesAvoid prolonged centrifugation
Serum SeparationAspirate serum without disturbing the cell layer.Separate within 2 hours of collectionInspect for hemolysis and turbidity
Labeling and TransportLabel tubes with all required information.N/ASend at room temperature unless freezing is required
Frozen Serum HandlingTransfer to plastic tubes and freeze if needed.Freeze immediately after separationStore at 0°C to -20°C or -70°C as required
Transport ConsiderationsUse frozen gel packs for frozen samples.Keep frozen until pickupMaintain frozen state during transport

Serum samples must be separated from cells within two hours of venipuncture. This step prevents cellular metabolism from altering the serum composition. Allow the blood to clot for 30–60 minutes at room temperature. Do not disturb the tube during this period. After clotting, centrifuge the tube for up to 10 minutes. Carefully aspirate the serum, avoiding the rbcs and wbcs at the bottom. Inspect the serum for hemolysis or turbidity, which can indicate contamination or poor sample quality.

Note: Delayed centrifugation beyond 3–8 hours at room temperature can cause significant changes in analytes such as potassium, urea, and enzymes. Laboratories should process serum samples promptly to maintain accuracy.

Sample Handling and Labeling

Proper sample handling and labeling are essential for traceability and reliable results in the separation of plasma and serum from blood. Laboratories follow strict protocols to prevent mix-ups and maintain sample integrity.

  • Use clear, chemical- and temperature-resistant labels with permanent adhesives. Avoid handwritten labels to reduce errors.
  • Include essential information on each label: protocol number, subject or animal number, visit or time, matrix, anticoagulant, and a unique identifier such as an accession number.
  • Do not use personal identifiers like names to protect privacy.
  • Place labels on the tube body, not on the cap or near moisture-prone areas. This practice prevents detachment and allows visual inspection of sample volume.
  • Employ barcodes or QR codes for efficient tracking and integration with electronic systems.
  • Record all labeling activities in traceability logs, including dates, times, operator identity, and sample status.
  • Maintain chain of custody by documenting sample location, storage conditions, and any time spent outside storage. Track the number of freeze-thaw cycles for each sample.
  • Use Laboratory Information Management Systems (LIMS) when available to maintain audit trails and improve traceability.
  • Store plasma and serum samples under conditions that preserve analyte stability. Refrigerate or freeze samples immediately after centrifugation as required.
  • Prepare a shipment inventory for each batch of samples, detailing all identifiers and storage conditions. Ship samples with dry ice or refrigerated packs to maintain stability during transport.

International standards from organizations such as ICSH, CLSI, and EFLM recommend labeling tubes before collection whenever possible. Labels should never fully wrap the tube, ensuring that laboratory staff can inspect the sample visually. Following these best practices reduces the risk of misidentification, contamination, and sample loss.

Improper handling of plasma and serum samples can lead to issues such as fibrin strands, microclots, hemolysis, and cellular contamination. These problems compromise the accuracy of laboratory assays and may require re-testing, increasing workload and costs.

The separation of plasma and serum from blood relies on precise timing, careful handling, and strict adherence to labeling protocols. By following these steps, laboratories can ensure high-quality plasma and serum samples for research and clinical applications.

Best Practices and Troubleshooting

Avoiding Hemolysis

Hemolysis, the rupture of rbcs, remains a leading cause of sample rejection in laboratory research. This problem affects the accuracy of quantitative analysis and reduces the purity of plasma and serum. Most hemolysis occurs during blood collection or handling. The following table summarizes common causes and strategies to minimize hemolysis:

Cause of Hemolysis During Plasma/Serum SeparationEvidence-Based Strategy to Minimize RiskSupporting Evidence
Blood withdrawal technique (e.g., incorrect needle size, excessive suction, prolonged tourniquet)Use straight needles for venipuncture; avoid IV starts when possible; draw blood from antecubital sites if IV starts are usedSupported by multiple studies including systematic reviews and quality improvement studies
Sample handling and processing (e.g., improper tube mixing, delayed processing, jarring transportation)Implement strict laboratory guidelines for sample handling and timely processingMajor pre-analytical factors causing in vitro hemolysis
Use of vacuum tubes with high suction pressureUse low vacuum tubes especially in sensitive populations like pediatric patientsStudies show reduction in hemolysis with low vacuum tubes

Laboratories should gently invert tubes after collection, avoid using IV catheters, and process blood quickly. Proper technique during white blood cell isolation also reduces cell damage. Using a blood plasma separator can further protect rbcs and wbcs from mechanical stress, improving sample integrity.

Preventing Contamination

Contamination can compromise the isolation and purity of plasma and serum, affecting downstream quantitative analysis. Laboratories follow these best practices:

Common errors include clotted samples, improper mixing, and labeling mistakes. The chart below shows the main reasons for sample rejection:

Strict adherence to protocols and the use of technologies like barcoding help reduce contamination and improve the reliability of blood cell isolation.

Storage and Transport

Proper storage and transport preserve the integrity of plasma and serum samples. Laboratories use the following steps:

  1. Select the correct color-coded tube for blood collection.
  2. For serum, allow blood to clot for at least 30 minutes; for plasma, mix with anticoagulant before centrifugation.
  3. Transfer plasma or serum into leak-proof plastic tubes.
  4. Use DOT-compliant transport tubes and pack samples in temperature-controlled racks.
  5. Follow DOT and IATA regulations for shipping.

Plasma and serum remain stable at 4°C for up to six months and at −20°C for up to one year. For long-term storage, −80°C is recommended to prevent degradation of sensitive analytes. Laboratories should minimize freeze-thaw cycles and use gradual thawing methods to maintain sample quality. Temperature fluctuations can alter concentrations of glucose, potassium, and other analytes, so prompt separation and cooling are essential.

Tip: Using a blood plasma separator and following best practices for storage and transport ensures high sample purity and reliable results in laboratory research.

separation-of-plasma-from-blood

Conclusion

Laboratory professionals achieve high-quality plasma and serum samples by following essential steps and using the right materials. The table below outlines key recommendations:

Step/AspectSerum SeparationPlasma Separation
Clot Formation Time30–60 minutes at room temperatureN/A
Holding TemperatureAfter clotting, hold at 4 °C for ≤4 hHold at 4 °C for ≤4 h before processing
Centrifugation TimingImmediately after clot formation or within 4 hImmediate processing or within 4 h
Collection TubesTubes without additives, for serumEDTA tubes preferred for plasma
Anticoagulant ChoiceN/AEDTA preferred
Temperature ControlRoom temp for clotting; 4 °C for holding; −80 °C for storageSame as serum; control during collection, transport, storage
AliquotingPrepare small aliquotsSame as serum
DocumentationRecord all handling times, temperatures, stepsSame as serum
Light SensitivityProtect from lightSame as serum

Strict adherence to best practices—such as using blood plasma separator, proper tube, and correct centrifugation—reduces errors and improves sample integrity. Studies show that compliance with guidelines enhances laboratory result quality, minimizes hemolysis, and ensures reliable data for research and clinical care.

FAQ

What Is the Main Difference Between Plasma and Serum?

Plasma contains clotting factors, while serum does not. Plasma comes from blood treated with anticoagulants. Serum forms after blood clots. Researchers often use a blood plasma separator to isolate plasma for laboratory analysis.

Why Do Laboratories Use Blood Plasma Separator?

Blood plasma separator helps laboratories quickly and gently separate plasma from blood cells. These devices reduce hemolysis and contamination. They also work well in settings without access to centrifuges.

How Can Hemolysis Be Prevented During Blood Collection?

Staff should use the correct needle size and avoid excessive suction. Gentle mixing and prompt processing help prevent hemolysis. Using a blood plasma separator can further protect red blood cells from damage.

How Should Plasma and Serum Samples Be Stored?

Laboratories store plasma and serum at 4°C for short-term use. For long-term storage, they freeze samples at −20°C or −80°C. Proper storage preserves analyte stability and prevents sample degradation.

Can Plasma and Serum Be Used Interchangeably in All Tests?

No. Some tests require plasma because it contains clotting factors. Others need serum to avoid interference from those proteins. Researchers must choose the correct sample type and separation method for accurate results.

If you are interested in our blood plasma separator, please fill out below form or send email to info@bloodplasmaseparator.com

    * Name:

    * Email:

    * Phone:

    * WhatsApp:

    * Subject:

    * Message:

      * Name:

      * Email:

      * Phone:

      * WhatsApp:

      * Subject:

      * Message:

      We use cookies in order to give you the best possible experience on our website. By continuing to use this site, you agree to our use of cookies.
      Accept