Opens in a new tab
BPS - focus on blood plasma separator manufacturing
blood-plasma-separator-9

Separation of Plasma and Serum from Whole Blood for Hormone Testing

separation-of-plasma-and-serum-from-whole-blood

Accurate separation of plasma and serum from whole blood remains essential for reliable biomarker measurement in hormone testing. Proper preparation and handling of blood samples help preserve proteins and maintain the integrity of proteomics data. Centrifugation stands as the standard method for blood plasma separation, yielding high-purity plasma and serum by removing red blood cells without protein loss. Laboratories prefer plasma and serum obtained through this preparation because these samples reflect true hormone concentrations. Prompt handling, correct tube selection, and timely preparation of whole blood samples reduce biomarker degradation. Blood plasma separator offers alternative preparation for proteomics, though centrifugation provides unmatched accuracy for hormone biomarker testing. Delayed preparation or improper handling of blood can lead to protein breakdown and compromise serum and plasma quality, affecting proteomics and biomarker results.

Key Takeaways

  • Choose the right blood collection tubes and anticoagulants to protect proteins and ensure accurate hormone testing.
  • Use centrifugation at recommended speeds and times to separate plasma or serum effectively without damaging proteins.
  • Process blood samples quickly and store them properly, ideally at very low temperatures, to keep hormones stable.
  • Handle blood samples gently to avoid hemolysis, which can interfere with hormone measurements and test results.
  • Blood plasma separator offers a portable alternative but centrifugation remains the most accurate method for hormone testing.

Materials and Tubes

Anticoagulants for Plasma

Blood plasma separation relies on the use of specific anticoagulants to prevent clotting during sample preparation for serum/plasma profiling. Laboratories select tubes based on the type of profiling, the stability of proteins, and the requirements of proteomics protocols. The most common anticoagulants include EDTA, sodium citrate, and heparin. Each anticoagulant affects the fractionation of blood components and the stability of peptides and proteins.

  • EDTA Tubes (Purple Top): EDTA binds calcium, stopping the clotting process. These tubes are widely used in hematology and proteomics profiling. Plasma collected in EDTA tubes preserves peptides and proteins, making it suitable for hormone and proteomics assays.
  • Sodium Citrate Tubes (Light Blue Top): Sodium citrate reversibly binds calcium. These tubes are mainly used for coagulation studies but can support plasma profiling in some biochemical and proteomics tests.
  • Heparin Tubes (Green Top): Heparin inhibits thrombin, preventing clotting. Heparin tubes are preferred for plasma hormone assays that require rapid processing and higher sample volume. They support standardized protocols for serum/plasma sampling in proteomics and peptide profiling.

Plasma collected with these anticoagulants allows for efficient fractionation and minimizes protein degradation. Proper blood collection and preparation protocols ensure that peptides and proteins remain stable for downstream proteomics analysis.

Serum Collection Tubes

Serum collection tubes play a critical role in blood profiling and proteomics. The choice of tube impacts the stability of proteins and peptides during preparation and storage. Laboratories often use silica-based or thrombin-based tubes for serum profiling.

Tube TypeClotting MechanismUse in Proteomics and Hormone Profiling
Silica-based Serum Tubes (SST™)Silica particles activate clotting (~30 min)Preferred for hormone and proteomics assays due to stability and purity
Thrombin-based Serum Tubes (RST™)Thrombin accelerates clotting (5-10 min)Used for rapid serum profiling when time-sensitive
Plain TubesNo additive; natural clottingUsed for basic serum profiling; less stable for some proteins and peptides

Serum separator tubes (SSTs) contain a gel barrier that separates serum from blood cells after centrifugation. This barrier reduces hemolysis and improves the stability of proteins and peptides during storage. However, some hormones and peptides may degrade or adsorb differently depending on the tube type and storage conditions. For example, intact parathyroid hormone remains more stable in plasma collected in EDTA tubes than in serum from plain or SST tubes, especially if processing is delayed. SSTs offer better stability than plain tubes but may not protect all proteins equally.

Proper blood collection, preparation, and fractionation protocols help maintain the integrity of proteins and peptides for accurate proteomics profiling. Choosing the right tube ensures reliable blood plasma separation and supports high-quality biomarker analysis.

Separation of Plasma and Serum from Whole Blood

Centrifugation Steps

Centrifugation remains the gold standard for the separation of plasma and serum from whole blood in biomarker profiling and proteomics. This process ensures high-quality fractionation of proteins and peptides, which is essential for accurate biomarker identification by mass spectrometry and biomarker discovery. Laboratories follow precise preparation protocols to maximize the stability of proteins and peptides during serum/plasma fractionation.

Step-by-step process for plasma separation:

  1. Collect whole blood in tubes containing the appropriate anticoagulant for plasma profiling.
  2. Gently invert the tube several times to mix the anticoagulant with the blood.
  3. Place the tube in a balanced centrifuge.
  4. Centrifuge at 1500–3000xg for 10–15 minutes, as recommended by most manufacturers. Some recent studies show that 5 minutes at 3000xg can also achieve optimal plasma separation for most analytes, except for certain enzymes like LDH.
  5. After centrifugation, observe three distinct layers:
    • The top layer contains clear plasma, rich in proteins, peptides, and electrolytes.
    • The middle buffy coat consists of white blood cells and platelets.
    • The bottom layer contains packed red blood cells.

Step-by-step process for serum separation:

  1. Collect whole blood in a tube without anticoagulant or with a clot activator for serum profiling.
  2. Allow the blood to clot at room temperature for 30–60 minutes (or 5–10 minutes for rapid serum tubes).
  3. Centrifuge at 1500–3000xg for 10–15 minutes.
  4. After centrifugation, identify the three layers as with blood plasma separation, but the top layer is serum, which lacks clotting factors.

Tip: Always use a pipette to carefully aspirate the plasma or serum layer. Avoid disturbing the buffy coat to prevent contamination with white blood cells or platelets, which can affect proteomics profiling and biomarker identification.

Centrifugation speed and duration guidelines:

  • Standard protocols recommend 10–15 minutes at 1500–3000xg for both plasma and serum.
  • Shorter centrifugation times (5 minutes at 3000xg) may be suitable for most routine analytes, but longer times are needed for coagulation tubes or when platelet-poor plasma is required.
  • Mechanical separator tubes, such as BD-Barricor, allow even shorter centrifugation times (3–5 minutes at 3000–4000xg).

Three-layer result after centrifugation:

LayerTypical AppearanceComposition
Top layerLight yellow fluidPlasma or serum: water, proteins, peptides, electrolytes
Middle layerThin white layerBuffy coat: white blood cells, platelets
Bottom layerDense, redRed blood cells

Timing and temperature matter:
Prompt processing of whole blood is critical for preserving proteins and peptides during serum/plasma fractionation. Delays in centrifugation, especially at room temperature, can cause significant decreases in hormone and biomarker stability. For example, ACTH levels decrease by 8–12% if centrifugation is delayed for 2–4 hours at room temperature, compromising measurement accuracy. Immediate centrifugation or storage at 4°C within 2 hours maintains stability for up to 8 hours.

ConditionTime to CentrifugationTemperatureStability of ACTH (% change)Recommendation
Immediate centrifugation0 hours4°C<5% change up to 8 hoursStable; accurate measurement ensured
Delayed centrifugation2–8 hours4°C<5% change up to 8 hoursStable if stored at 4°C before centrifugation
Delayed centrifugation2–4 hoursRoom temp8.1% to 12.4% decreaseSignificant decline; accuracy compromised
Storage after centrifugation24 hours4°C>10% decreaseNot recommended; significant hormone degradation

Note: Always process blood samples as soon as possible to ensure reliable biomarker discovery and proteomics profiling.

Membrane Blood Plasma Separator Method

separation-of-plasma-and-serum-from-blood

Blood plasma separator offers an alternative to traditional centrifugation for the separation of plasma and serum from whole blood. These microfluidic devices use specialized membranes to filter out blood cells, allowing plasma to pass through for downstream proteomics and biomarker profiling. This method supports rapid preparation and can integrate with automated or point-of-care workflows.

MethodPlasma Purity (%)Plasma Yield (%)Additional Notes
Membrane-based microfluidic (HCHPS0.5)~47.08~17.93Continuous, high-throughput, lower hemolysis, suitable for integration with downstream analysis
Membrane-based microfluidic (HCHPS0.25)~63.81~9.69Higher purity but lower yield compared to HCHPS0.5
Membrane-based microfluidic (HCHPS1)~18.44~34.68Highest yield among microfluidic designs but lowest purity
Traditional centrifugation~99.9~46.78High purity and yield, but requires bulky, expensive equipment and longer processing times

Membrane-based blood plasma separation provides lower plasma yield and purity compared to centrifugation, but it reduces hemolysis and enables continuous, high-throughput fractionation. This approach is especially useful for proteomics profiling and biomarker identification in settings where traditional centrifugation is impractical.

Recent advancements in blood plasma separation include paper-based assays. These devices use clotting activators on wax-channeled filter paper to rapidly induce clotting and trap blood cells. Serum then wicks through microfluidic channels, enabling direct serum/plasma fractionation without complex equipment. Paper-based assays have demonstrated compatibility with hormone testing, such as thyroid-stimulating hormone measurement, and offer rapid, cost-effective, and portable solutions for biomarker discovery and proteomics profiling.

Paper-based plasma separation assays provide several advantages:

  • Lower cost and simple fabrication
  • Rapid diagnostic capability
  • Easy operation and transport
  • Compatibility with both invasive and non-invasive fluids

These devices support biomarker identification and proteomics profiling in resource-limited or point-of-care settings, although their sensitivity and specificity may not always match conventional spectrometry-based methods.

Tip: For high-throughput biomarker discovery and proteomics profiling, laboratories should validate the chosen blood plasma separation method for their specific analytes and workflows.

Handling and Storage for Testing

Preventing Hemolysis

Proper handling of blood samples is essential for accurate biomarker measurement in proteomics. Hemolysis, which occurs when red blood cells break down, releases intracellular proteins and peptides that interfere with hormone assays. This process can cause both positive and negative biases in plasma and serum hormone concentrations. Hemoglobin and other cell contents disrupt immunoassays, leading to unreliable biomarker results. To prevent hemolysis during blood plasma separation, laboratories follow these best practices:

  • Gently mix tubes containing anticoagulants 4-6 times.
  • Use a 21- to 22-gauge needle for routine blood collection.
  • Avoid drawing blood from hematomas or using excessive force.
  • Let the venipuncture site dry before collection.
  • Prevent frothing and avoid traumatic or probing venipuncture.
  • Limit tourniquet time and avoid fist clenching.

Careful handling during blood collection and processing preserves the integrity of proteins and peptides, supporting reliable proteomics and biomarker testing.

Storage and Transport Guidelines

Prompt separation of plasma or serum from whole blood is critical for maintaining hormone and biomarker stability. Studies show that delays in processing allow blood cells to alter hormone concentrations, affecting the accuracy of proteomics analysis. Immediate centrifugation and refrigerated storage (2-8°C) help maintain analyte stability. Most guidelines recommend separating plasma or serum within a few hours, ideally within 6 to 8 hours, to preserve proteins and peptides.

After blood plasma separation, storage temperature becomes the key factor. Storing plasma and serum at −70°C or lower, preferably at −80°C, best preserves hormone integrity. Storage at 4°C is only suitable for short periods, usually less than 3 hours, because analyte instability increases over time. Minimizing freeze-thaw cycles and avoiding temporary thawing incidents further protect proteins and peptides.

Condition/ParameterPlasma StabilitySerum Stability
Room temperatureStable up to 4 daysLess stable
4°C (refrigeration)Stable up to 8 daysStable up to 24 hours
−20°C (freezing)Stable up to 8 daysStable up to 8 days
−70°C to −80°C (freezing)Optimal for long-termOptimal for long-term

Proper handling, storage, and transport of blood, plasma, and serum samples ensure accurate biomarker discovery and proteomics profiling. Delayed processing or improper storage can degrade proteins and peptides, leading to unreliable testing results.

Common Pitfalls in Biomarker Testing

Tube Selection Errors

Tube selection plays a critical role in biomarker discovery and clinical diagnosis. Laboratories often encounter errors when choosing blood collection tubes with inappropriate additives. Surfactants and other non-inert additives in tubes can interact with proteins and peptides, leading to significant alterations in hormone concentrations. These changes affect the accuracy of biomarker identification and proteomics analysis. The following table summarizes how tube additives impact hormone assays:

AspectEvidence Summary
Tube additives involvedSurfactants and other non-inert additives in blood collection tubes
Hormones affectedTotal triiodothyronine (TT3), total thyroxine (TT4), cortisol
Effect on assaysStatistically and clinically significant alterations in hormone concentrations
MechanismAdditives interact with assay components or analytes, causing interference in immunoassays
Reformulation effortsReduction of surfactant content in tubes improved but did not fully eliminate interference
Quality control implicationsQC specimens processed in the same tubes as patient samples reveal additive-related interference; emphasizes need for truly inert additives
Pre-analytical errorTube additives represent a significant source of pre-analytical error affecting hormone assays
RecommendationsUse of inert additives and matching QC specimen processing to patient samples to detect interference

Selecting the correct tube ensures reliable blood plasma separation, accurate fractionation, and supports high-quality biomarker-related studies.

Delayed Processing

Delayed processing of blood samples can compromise biomarker discovery and proteomics workflows. Immediate fractionation preserves proteins and peptides, but some hormones, such as thyroid stimulating hormone (TSH), remain stable even after a 24-hour delay at room temperature or up to 7 days at 4°C. Most analytes in plasma and serum show stability with delayed centrifugation up to 12 hours. However, certain proteins and peptides, including potassium and LDH, may degrade. Prompt blood plasma separation and storage at 4°C increase analyte stability, supporting accurate identification and proteomic patterns for disease diagnosis. Laboratories should always prioritize timely fractionation to minimize the risk of degradation, especially for sensitive proteins and peptides.

Interference Factors

Several interference factors can affect biomarker identification and proteomics analysis in blood samples:

  • Haemolysis releases intracellular proteins and peptides, which interfere with hormone measurements and spectrometry-based assays.
  • Icterus (high bilirubin) and lipaemia (high lipid content) cause assay interference by altering absorbance or scattering light, impacting spectrometry and immunoassays.
  • Monoclonal gammopathies introduce paraproteins that disrupt antigen-antibody binding, complicating biomarker discovery and identification.

Laboratories can minimize interference from lipemia, hemolysis, or icterus by using ultracentrifugation for removal of high abundance proteins and lipids, applying direct potentiometry, and establishing their own interference thresholds. Pre-analytical measures such as fasting and careful blood collection reduce the occurrence of these issues. High abundance protein depletion and removal of high abundance proteins enhance the accuracy of proteomics and biomarker-related studies. Consistent quality control and validation of blood plasma separation ensure reliable fractionation and identification of proteins and peptides.

Tip: Always perform laboratory-specific interference studies to support robust biomarker discovery and proteomics workflows.

separate-plasma-and-serum-from-whole-blood

Conclusion

Accurate blood plasma separation supports reliable hormone and biomarker testing in proteomics. Laboratories should follow these essential steps:

  1. Select the correct blood collection tubes to avoid interference with proteins.
  2. Use the right anticoagulant for plasma samples and control clotting times for serum.
  3. Standardize blood collection and handling to protect proteins and peptides.
  4. Centrifuge samples at optimal speed and time for effective separation.
  5. Filter samples gently to remove clots, preserving proteins for proteomics.
  6. Maintain consistent storage conditions to prevent protein degradation.
  7. Validate protocols to ensure reproducibility in proteomics studies.

Practical tip: Blood plasma separator offers portable, cost-effective alternatives for blood plasma separation, especially in resource-limited settings. These methods enhance patient comfort and support a wide range of proteomics applications.

FAQ

What Is the Main Difference Between Plasma and Serum?

Plasma contains clotting factors, while serum does not. During blood plasma separation, plasma comes from blood with anticoagulant, and serum comes from clotted blood. Both support hormone testing, but some tests require one over the other.

Why Does Prompt Processing Matter for Hormone Testing?

Delays in blood plasma separation can cause hormone breakdown. Fast processing keeps hormone levels stable. Laboratories process samples quickly to ensure accurate results for hormone and biomarker tests.

Can Blood Plasma Separator Replace Centrifugation?

Blood plasma separator offers a portable option. They work well in clinics without centrifuges. However, centrifugation gives higher plasma purity and yield. Laboratories choose the method based on their needs.

How Should Plasma and Serum Samples Be Stored?

Store plasma and serum at −70°C or lower for long-term use. Short-term storage at 4°C works for a few hours. Proper storage prevents protein and hormone degradation after blood plasma separation.

If you are interested in our blood plasma separator, please fill out below form or send email to info@bloodplasmaseparator.com

    * Name:

    * Email:

    * Phone:

    * WhatsApp:

    * Subject:

    * Message:

      * Name:

      * Email:

      * Phone:

      * WhatsApp:

      * Subject:

      * Message:

      We use cookies in order to give you the best possible experience on our website. By continuing to use this site, you agree to our use of cookies.
      Accept